New release for Bimeye
Project Configuration
- New option in Project Vizard to start from Global Project Templates developed and administrated by Tribia
- Select the desired template and give the project a name
- After selecting the project, the user can select which configurations from the template they would like to copy to the new project just as with the Start From Existing Project option
Parameters and Parameter Groups
Sync Direction
- Improved the parameter configuration by adding the ability to change a parameter’s Sync Direction from Disabled to Sync To Bimeye or Sync From Bimeye
- Note: Any existing value in Bimeye will be overwritten after next sync from model if Sync Direction is set to Sync To Bimeye. In the same manner, values will also be overwritten in the model if we change the Sync Direction from Disabled to Sync From Bimeye
- Previously it was only possible to change the Sync Direction between the two options related to model sync, Sync To Bimeye/Sync From Bimeye
New Parameter Type – Value List
- Value List is now implemented as a new type of parameter. An editable list of values where all the different values used are visible for that specific parameter
- You can search, assign a value from the list, or add a new value by double clicking the Cell in the Data Grid
- Editing a value will change that value on all objects with that specific value, for example editing the value Purple to Dark Blue in the image below will change all four occurrences of Purple
- This new Parameter Type is available for the parameter Data Type Text and URL
- It is also available to be used in Items, that is parameter groups with a leading parameter
- Imported values from Microsoft Excel will be added to the list of values
- Parameters set to Sync To Bimeye cannot be ValueLists
Tooltips
- CustomTooltips for parameters, data type and parameter groups are now visible when hovering over the grid column headers
- The Custom Tooltip is specified in the parameter configuration
Synchronization
- Logs can be downloaded if sync was canceled manually to get more details about the synchronization
Room
- Warning implemented for when creating new Room parameters if they change sync direction to FROM Bimeye that the parameter cannot be used for new Bimeye rooms
Bugfixes
Phases*
- Phase selection now work on Grid filter Data and 3D view. User can select phase from dropdown for selected model and it will be reflected on room projected parameters for instances.
Grouped Revisionreports
Changelog report now recognize the $ {t1} command on Type parameters
*Only available for models synchronized with Autodesk Revit